- Re: Starter Help!Historical mailing list - Michael CollumSun, 14 Feb 2010 14:25:29 -0500That uninsulated wire between the starter body and the solenoid is not a ground. It is the main wire from the solenoid to the...
- Re: HELP!!! Van won't start!!!Historical mailing list - Victor MontgomeryMon, 25 Jan 1999 08:21:53 EST...Following that check your starter and solenoid. If the starter is bad, it is usually prudent to replace the solenoid at the same time...
- Starter Solenoid SpecificationsHistorical mailing list - Michael A. RadtkeWed, 13 Sep 2000 08:49:04 -0700Hello, Can you point me to a web site that shows starter solenoid specifications? I am looking for the electrical information such as control...
- Re: Starter solenoid?Historical mailing list - Larry AlofsFri, 22 Aug 2003 09:55:26 -0500...Tracey Estevez wrote: > Does anybody know if it is possible to purchase a solenoid seperate from the starter for the 85 Vanagon? > > -T >
- Re: starter woe...Historical mailing list - westydriverThu, 7 Nov 2002 17:15:18 -0700that is what the solenoid does. it sends the contact forward connecting the high current lead to the starter and pushing the gear out...
- Re: 82 ex-Diesel Starter TroubleHistorical mailing list - Sean BartnikFri, 20 Mar 1998 12:25:48 EST...You can also test the solenoid by putting your voltmeter in line between the second post on the solenoid (where the wire connects to...
- Re: Starter Solenoid?Historical mailing list - Marla StelkSun, 4 May 2003 13:50:18 -0400...Starter Solenoid? >Date: Sat, 3 May 2003 09:42:05 -0400 > >So let me get this straight. I have the delay....sometimes not starter...
- Re: Solenoid relayHistorical mailing listTue, 25 Jun 1996 08:39:11 -0700...I think 30 would be from the battery and 15 would be out >to the solenoid, but I'm not sure what the numeric...
- Starting problems...Historical mailing list - Todd LastSun, 29 Dec 2002 16:05:40 -0800...However, if I whack the side of the starter and solenoid, it will usually start afterwards - but not always. (I remembered this trick from...
- Starter solenoid powered by fuel pump circuit....arrrrgg...long...help!!!Historical mailing list - Richard GolenThu, 26 Jun 2014 16:46:43 -0400...The switch power to the starter solenoid is getting current when the switch is turned to start, and when the ignition is in the...
- Re: Continuous Duty Solenoid vs Starter Solenoid; Visual Difference?Historical mailing list - Neil NTue, 20 Oct 2015 16:59:01 -0700...I entered "12 volt starter solenoid" in google images, and found this on amazon http://tinyurl.com/oywgpzl but then it does show "continuous...
- Re: won't startHistorical mailing list - Don LancasterThu, 27 Mar 1997 12:23:25 -0700...The cause is not enough voltage reaching the starter solenoid terminal. Or the solenoid itself needing cleaned and lubed (NOT an easy chore) -- Many...
- starter problems-dieselHistorical mailing list - Madeline Mullen/Ed LoweFri, 3 Jul 1998 21:00:38 -0800...The wire that led to the starter from the key was wired to the "solenoid" and the terminals on the solenoid were wired from...
- Re hot solenoid not kickingHistorical mailing listSat, 6 Jul 1996 17:02:12, -0500...trip report starter problem Sean (via Linda Bartnik) had a starter (solenoid) problem when hot..... So you liked King's Dominion? If we go...
- Re: WAS: Starter Motor... Failure: NOW: 50 Circuit Weirdness. ECU Related?Historical mailing list - Mike BSat, 15 Dec 2012 16:38:40 -0500...The solenoid has two independent windings inside, the big main one that has the power to pull the solenoid piston in, along with the...
- Re: Starter/relay/switch problem fixedHistorical mailing list - Scott Daniel - TurbovansWed, 25 Jul 2012 11:46:53 -0700...The solenoid is not the weak area. The electrical path through the solenoid depends on conductivity through the brushes and commutator I believe. And...
- Re: dragging starterHistorical mailing list - Karl F. BlossFri, 3 Apr 1998 19:16:15 -0500Read all about the solenoid and why it's not the proper fix from Bob Hoover's Sermons: http://www.type2.com/sermons/liturgy...
- starter solenoid current remeasuredHistorical mailing list - Larry AlofsThu, 29 Jan 2009 09:54:07 -0600A couple of weeks ago I stated that I had measured the starter solenoid current and got a rather surprising result of 37 A...
- Re: Continuous Duty Solenoid vs Starter Solenoid; Visual Difference?Historical mailing list - Neil NTue, 20 Oct 2015 23:24:00 -0700...Reading about solenoids as used in landing gear here: http://saginawwings.com/monty-answerman/relay.htm this excerpt shed some more light: "The intermittent...
- Re: vanagon starter questionHistorical mailing list - phil cainSun, 11 Sep 2005 16:40:07 -0700...Could be bad wiring from the ignition switch(giving low voltage when hot), could be a sticky solenoid, could be corroded wires at the...
- Re: Starter solenoid powered by fuel pump circuit....arrrrgg...long...help!!!Historical mailing list - Dennis HaynesFri, 27 Jun 2014 02:29:37 -0400...Anyway if the circuit is not right when the alternator turs on it can keep the starter solenoid from dropping out. The starter signal...
- Re: no cold start/hard start relay kitHistorical mailing list - Stan WilderSun, 20 Jan 2002 18:15:13 -0600The problem I've found with starters is that the piston in the solenoid gets sticky from the dust and oil that gets on...
- No spark, helpHistorical mailing list - alfred bagdanMon, 31 Jul 2006 13:39:08 -0600...I checked for spark from solenoid, no spark. Exchanged solenoids, still no spark. Cleaned groundwires still no luck. Van ran great just yesterday. Can...
- Re: starter solenoid buzzing and overehating? (long)Historical mailing list - Dennis HaynesTue, 28 Jan 2003 22:45:45 -0500...weak battery + voltage drop from switch to solenoid + sticky solenoid caused that). That would also explain the solenoid getting stuck in the on position...
- Re: Vanagon Syncro Delayed StartHistorical mailing list - John HungThu, 28 Aug 1997 17:13:35 -0500...Current flows in the solenoid winding, creating a magnetic field. 2. Magnet field pulls on a big metal plunger in the solenoid. 3. Plunger...
- Re: 82 won't crank was 82 won't start when hotHistorical mailing list - Higginbotham, David A.Tue, 21 Oct 2003 06:33:39 -0400...You need to find out if power(and how much) is getting to the solenoid when you turn the key to the start position...
- Re: solenoid vs ignition switch for non-startHistorical mailing list - neilMon, 9 Apr 2007 09:50:31 -0700...That tells > me the ignition switch is not the problem--and I am back > to the solenoid. Is that diagnois correct? > > Anything else before...
- Re: FW: Starter problemsHistorical mailing list - joe brownMon, 18 Nov 2002 19:56:44 -0800Pull the starter, remove the solenoid -snip- My solenoid screws wouldn't budge with a screwdriver. I was ready to drill them out but...
- Re: Starting problems...Historical mailing list - Larry AlofsSun, 29 Dec 2002 18:40:09 -0600...In these cases I have found that cleaning or replacing the solenoid is only a temporary solution if it helps at all. The design...
- Starter Help!Historical mailing list - Kevin PlichtaSat, 13 Feb 2010 15:35:55 -0500...I here the fuel pump come on, there is 12v at the main starter lead and less than 4 at the solenoid when turning...
- Re: Intermittent StarterHistorical mailing list - Tim DemarestThu, 12 Oct 2006 15:56:55 -0400...Since hot-wiring at the solenoid worked, it could be an issue with the ignition switch, or the wire loop between the ig. switch...
- found solenoid sourceHistorical mailing list - Alistair BellFri, 17 May 2002 08:55:09 -0700Partial success, found 2 shops in town that sell the solenoids (for my diesel starter), one at Ca$34 the other at Ca$29...
- Re: no cold start/hard start relay kitHistorical mailing list - Mathieu BertrandSun, 20 Jan 2002 23:24:29 +0000...Cliquez ici > >The circuit from the ignition switch to the starter solenoid was poorly >designed and supplies just enough current to activate the solenoid...
- Re: common electrical problems in vanagonsHistorical mailing list - mdrillockTue, 15 Jul 2008 14:40:39 -0700...Mark Larry Alofs wrote: > I nominate the mickey mouse circuit that activates the starter solenoid. By > my measurement, the solenoid draws about 37 amps...
- Re: '82 Diesel vanagon. Starter isn't turning over.Historical mailing list - Brett NeWed, 24 Aug 2022 11:10:28 -0700First try a remote starter (or jumper wire ) between positive battery and the solenoid. This will narrow it down to either a starter/solenoid...
- Starter or Solenoid?Historical mailing list - John SchaperWed, 29 Nov 2000 07:18:35 -0800...Based on these symptoms, is it probably the starter or the solenoid?
- Can I buy just a solenoid?Historical mailing list - Anonymous DigestSat, 24 Jan 2004 18:57:31 -0700I have a friend with starting problems, and it sounds like it might be the solenoid. Haven't actually climbed under and done any...
- Re: starter wiringHistorical mailing list - Larry AlofsSun, 28 Apr 2002 11:39:51 -0500...solenoid to > try and start the motor if I wanted to. > Anything that make a connection between the large (+) cable on the solenoid to...
- Re: need help with starter problem, 1990 Vanagon GL, 4spd 2.1LHistorical mailing list - Larry AlofsWed, 20 Jan 2010 06:49:56 -0600...This symptom is usually caused by the deterioration of the solenoid, wiring, ignition switch or all of the above. You can see part of...
- Starter motor updateHistorical mailing list - Peter KroghWed, 30 Aug 2000 09:47:43 EDT...Does the banging on starter indicate any particular problem? (Faulty ground, solenoid or starter?) I noticed that the red and black wire going to...
- Re: Stuck Solenoid????Historical mailing list - JackTue, 7 Sep 2004 23:46:45 -0800...If it was "worn" enough to not pass enough current to drive the solenoid (assuming a good solenoid, of course), that probably means there...
- Re: Power steering boost valve?Historical mailing list - Karl WolzWed, 27 Sep 2000 07:22:09 -0700Mark, To where do the wires from the solenoid lead? If to the switch on the power steering pump, then it is the PS...
- need a pic of the starter/solenoid wiresHistorical mailing list - GinaThu, 1 Jul 2004 19:00:05 -0400...I would appreciate it if someone has/could scan a diagram or pic of the starter and solenoid showing the wiring. I found a...
- Re: WAS: Starter Motor... Failure: NOW: 50 Circuit Weirdness. ECU Related?Historical mailing list - Scott Daniel - TurbovansSat, 15 Dec 2012 14:15:22 -0800...The solenoid has two > independent windings inside, the big main one that has the power to > pull the solenoid piston in, along with the...
- Re: Starting problems...Historical mailing list - Milo's KitchenSun, 29 Dec 2002 20:43:14 -0500...If the solenoid clicks but the starter does not operate, check the top-most (at the starter) big diameter wire for corroded connection (see...
- Dual Batt. info neededHistorical mailing list - neil neilThu, 20 Apr 2006 11:57:12 -0400...Have purchased solenoid from local RV shop to use for dual batt. setup. I have a good idea of how to wire, but need...
- Re: New Starter...Solenoid Hanging UpHistorical mailing list - Dennis HaynesThu, 26 Jun 2014 06:10:54 -0400...New Starter...Solenoid Hanging Up Hi, Just put in a new rebuilt Bosch starter in my 87. Worked well last night, this morning and...
- Re: starting problemsHistorical mailing list - The Bus DepotThu, 26 Jul 2001 17:25:31 -0400...When the engine is hot, the starter solenoid can require more juice to kick over. If there is a minor voltage supply problem it...
- Re: VANAGON FOR SALE? HELP Diagnosis needed STAT!Historical mailing list - Stephen T. KIRBY 610-454-3941Wed, 30 Apr 1997 07:43:00 -0400 (EDT)...It is caused by the resistance of the wire and connectors from the ignition switch to the starter solenoid. The resistance gets higher as...
- FW: URGENT: Stranded in Remote Area with disabled wife -Historical mailing list - Fitz-Randolph, DouglasMon, 24 Jun 2002 11:03:33 -0400...Stranded in Remote Area with disabled wife - please h elp! > Does it sound to anyone else like he may need the 'hard start > solenoid...
- Re: Starters...Historical mailing list - Jack ReedFri, 23 Jun 1995 10:54:27 -0600 (MDT)...Anybody out there equally > frustrated? Are you certain it's the solenoid and not the wiring/ignition switch that make the starter seem to...
- Starter-solenoid-relay problemsHistorical mailing list - Mark ThomaSun, 2 Aug 1998 12:25:23 -0400...Is my problem in the solenoid? and if so, what can go wrong with it? After all the solenoid is just a big electro...
- Re: Intermittent no startHistorical mailing list - Wolfgang ZieglerTue, 12 Sep 2000 20:21:13 -0400...Replacing the solenoid did not solve the problem. An additional wire connected to the 'hot' side of the solenoid terminal showed that under those...
- Re: Continuous Duty Solenoid vs Starter Solenoid; Visual Difference?Historical mailing list - Neil NTue, 20 Oct 2015 19:23:52 -0700...wrote: > Reading further, it seems that the continuous and intermittent duty > solenoids each have different coil types, thus resistance, due to > the amount of...
- Re: 88' wolfsburg Passenger door won't lockHistorical mailing list - Doktor TimSun, 5 Oct 2003 13:05:42 -0700...Could be the solenoid is hung by a fouled rod or if the solenoid goes click could be broken link. Something is jamming the...
- Re: '72 Bus Starter ProblemsHistorical mailing listThu, 27 Oct 94 11:34:53 MDT...The solenoid is designed to push the Bendix gear into contact with the flywheel. If the solenoid's electromagnet's windings are shot or...
- starter fixedHistorical mailing list - Alistair BellSat, 18 May 2002 15:37:19 -0700I installed the new solenoid in my starter (after lubing the bendix and bushing of the starter itself) and re-installed into van. Works...
- New Starter...Solenoid Hanging UpHistorical mailing list - Richard GolenWed, 25 Jun 2014 20:07:51 -0400...Then this evening when I started it up the solenoid/drive gear would not disengage. I can get the starter to disengage when I...
- starter solenoid buzzing and overehating? (long)Historical mailing list - TinkerManTue, 28 Jan 2003 16:14:11 -0800...weak battery + voltage drop from switch to solenoid + sticky solenoid caused that). That would also explain the solenoid getting stuck in the on position...
- Re: Start-Solenoid-fixHistorical mailing list - David BrodbeckThu, 1 May 2003 11:11:50 -0400...The starter solenoid has a fairly hefty current drain -- around 8 amps, IIRC. This current has to travel through a long run of small...