

Search messages and discussions
Search preserved mailing-list messages and current email and website contributions. Current posts are searchable before weekly archival. Recovery gaps remain possible. Words are matched together; try fewer terms if needed.
Page 1+: 60 results shown for Hall control unit.
Source-balanced relevance: matches from both collections are interleaved, with source dates breaking ties. Restoration time is not the original posting date.
- DigiJet Hall Control Unit Maint' Point & PollHistorical mailing list - OlRivrRatFri, 23 Feb 2018 10:21:12 -0700How many 1.9L H2OBoxer DigiJet owners have ever Cleaned & Reapplied Heatsink Compound on the Hall Control Unit ? ORR ~ DeanB
- Re: DigiJet Hall Control Unit Maint' Point & PollHistorical mailing list - Steve WilliamsFri, 23 Feb 2018 10:57:43 -0800...I haven't heard of the Hall Control Unit, so I'd be interested in learning more. I believe the DigiJet is the earlier...
- Need help to determine type of Hall control unitHistorical mailing list - George AverillTue, 13 Aug 2002 19:52:59 -0400...The unit currently installed has no numbers on it. The Bentley says that "Two different types of Hall control units can be installed." (Fairchild...
- Hall sender + ignition control unit electronicsHistorical mailing list - tinker manSun, 17 Jun 2012 21:37:28 +0300Just wondering - what electronics do the hall sender and the ignition control unit contain? I want this info to be better able to diagnose...
- Re: Idle stabilizerHistorical mailing list - John ClavinSat, 12 Jan 2002 11:45:01 -0600...Three wires connect the Hall sender to the Control unit. It is these three wires that are routed through the two plugs on the...
- Re: Idle stabilizerHistorical mailing list - Todd LastSat, 12 Jan 2002 15:30:58 -0800...Three wires connect the Hall > sender to the Control unit. It is these three wires that are routed through > the two plugs on the...
- Re: '85 Ignition Control UnitHistorical mailing list - David BeierlTue, 23 Mar 2010 20:00:04 -0400...Was looking at "Hall control unit" P 28.28 Bentley, but wrote >the wrong thing. I would call that a wrong label. 97.55...
- Re: '85 Ignition Control UnitHistorical mailing list - pdooleyTue, 23 Mar 2010 16:26:17 -0400...Re: '85 Ignition Control Unit >> > I don't know the WBX that well so was curious. Is this the Hall >> Sensor? >>Yup - the little...
- Hall sending unit???Historical mailing listThu, 26 Mar 1998 06:55:04 -0800...Anyone else experienced this? Did you replace just the Hall sending unit? The distributer? The control unit computer (gulp!!!)? Battery is good. Starter is...
- Cutting outHistorical mailing list - Robert KeezerSun, 1 Jul 2001 03:44:07 EDT...This can occur for a variety of reasons, but in this case, it was the Hall control unit. My engine management system is Digifant...
- Re: '85 Ignition Control UnitHistorical mailing list - neil nTue, 23 Mar 2010 13:20:16 -0800...Was looking at "Hall control unit" P 28.28 Bentley, but wrote the wrong thing. Yes of course. Sender is on the distributor. Thanks...
- Quantum no-start problem solved( no Vanagon content)Historical mailing list - Robert Keezer 19618-5th Ave so Seattle WA 98148Tue, 2 Nov 1999 03:44:27 EST...That got me thinking about two things, the coil, it was OK, and the Hall control unit, it was bad. Does anyone know what...
- 80 Westfalia probs.Historical mailing list - Marc EdwardsSat, 11 Jul 1998 16:28:30 -0700...1 from the Fuel Injection Control Unit which connects to injectors...etc and 1 that connects to the hall distributor, idle stabilizer...etc. The...
- Re: No spark in the DigifantHistorical mailing listTue, 12 Aug 1997 19:41:16 -0400 (EDT)...hall sender itself? If you didn't get a blip from the hall sender itself that is the faulty part not the control unit...
- No spark -- Ignition Control Unit?Historical mailing list - Geza PolonyWed, 9 May 2007 10:34:17 -0400...good per Bentley, and there's power to the Ignition Control unit (Hall control.) Still, there's no spark. The voltage test across the...
- Re: Idle stabilizerHistorical mailing list - David BeierlSat, 12 Jan 2002 13:54:43 -0500...I >suspect this control unit functions much as an electronic relay, switched >on and off by the Hall signal, and handling the higher currents...
- Hall control unit failure, was: Quantum no-start problem solved( no Vanagon content)Historical mailing list - BulleyTue, 2 Nov 1999 07:12:15 -0500...That got me thinking about two things, the coil, it was OK, and the Hall control unit, it was bad. Does anyone know what...
- a fuel pump relay storyHistorical mailing list - brian jThu, 12 Aug 2004 13:43:29 -0700a year after my Hall Control unit adventure, my van started doing the same thing again - occasionaly when I hit a bump, the motor...
- Re: Mystery Electrical TroubleHistorical mailing list - Steven DodsonMon, 29 Jul 2002 21:58:32 -0400...OK Hall sender unit test: (in bottom of distributor) OK Control unit test(EC, ECU): OK However the problem still occurs as it has...
- Re: bad hall control unit = no spark?Historical mailing list - Jonathan FarrugiaFri, 11 Mar 2005 17:50:05 -0500...Would a bad hall control unit cause this? The tiico reuses the > original digijet one, mine is the telefunken type, original to the van...
- Re: Hall Sender VideosHistorical mailing list - David BeierlFri, 29 Nov 2013 13:58:59 -0500...the idle control unit. He's just driving the input line to the ECU and ICU the same way that the Hall sender would...
- bad hall control unit = no spark?Historical mailing list - jeff kennedyFri, 11 Mar 2005 07:44:30 -0700...Would a bad hall control unit cause this? The tiico reuses the original digijet one, mine is the telefunken type, original to the van...
- No pulse at injectorsHistorical mailing list - Rico DagastinoTue, 22 Feb 2000 19:35:25 EST...at the control unit relay and the fuel pump relay. Both are working. I have power at the connection to the hall sender on...
- Re: Idle stabilizerHistorical mailing list - Todd LastSun, 13 Jan 2002 12:14:55 -0800...an idle stabilizer valve, and idle stabilizer control > >unit. > >The control unit is hooked to the Hall sensor, and also the stabilizer valve. > >You...
- Re: '85 Ignition Control UnitHistorical mailing list - David BeierlTue, 23 Mar 2010 16:03:41 -0400...The Hall sender is inside the distributor. This is the switching unit (Toyota calls them "igniters" which actually generates the primary spark impulse that...
- Re: Need help to determine type of Hall control unitHistorical mailing list - The Old Volks HomeTue, 13 Aug 2002 20:29:26 -0700...The Bentley says that "Two different types of Hall control units can be installed." (Fairchild or AEG). Does this mean that either will work...
- Re: Cutting outHistorical mailing list - Richard GolenSun, 1 Jul 2001 07:28:45 -0400...variety of reasons, but in this case, it was the Hall >control unit. > >My engine management system is Digifant ll, which is 88-92...
- Installing Idle stabalizer.Historical mailing list - Greg MarshallTue, 16 Apr 2002 16:42:58 -0400...Three wires run to the hall control unit, and three wires run of to the distributor. The idle stabilizer has to plugs, a short...
- Re: ECU firmware locationHistorical mailing list - tinker manMon, 17 Sep 2007 02:45:19 +0200...H) system with vacuum advance and all the rest, and HALL sender driving the HALL control unit that in turn drives the coil. TM
- Re: Hall sender + ignition control unit electronicsHistorical mailing list - Scott Daniel - TurbovansSun, 17 Jun 2012 14:45:19 -0700...scott On 6/17/2012 11:37 AM, tinker man wrote: > Just wondering - what electronics do the hall sender and the ignition > control unit...
- Re: Mystery Electrical TroubleHistorical mailing list - David BeierlMon, 29 Jul 2002 22:09:18 -0400...OK > >Hall sender unit test: (in bottom of distributor) OK > >Control unit test(EC, ECU): OK > >However the problem still occurs as it has...
- Re: Hall sender + ignition control unit electronicsHistorical mailing list - Old Volks HomeSun, 17 Jun 2012 14:06:01 -0700...com> wrote: > Just wondering - what electronics do the hall sender and the ignition > control unit contain? > I want this info to be better able...
- Re: DigiJet Hall Control Unit Maint' Point & PollHistorical mailing list - OlRivrRatFri, 23 Feb 2018 14:09:16 -0700...I haven't heard of the Hall Control Unit, so I'd > be interested in learning more. > > I believe the DigiJet is the earlier...
- Re: gremlins in ignitionHistorical mailing list15 Jan 97 07:54:23 PST...1) CA emisson controls so it has a halls control unit 2) It seems to die(ha ha) when I'm crusing at a...
- 1.9 Harness/ECU FreeHistorical mailing list - Bill MSun, 23 Dec 2012 14:07:35 -0500...It's a 1.9 ECU,Harness,idle control unit,and Hall control unit. Also has the black relay box. I have not tested...
- Re: '85 Ignition Control UnitHistorical mailing list - Dug SmithTue, 23 Mar 2010 13:19:03 -0700...Is this the Hall >> Sensor? >>Yup - the little box below the coil. > No 'tisn't. The Hall sender is inside the distributor. I know...
- Re: gremlins in ignitionHistorical mailing listWed, 15 Jan 1997 18:48:15 +0200...1) CA emisson controls so it has a halls control unit 2) It seems to die(ha ha) when I'm crusing at a...
- Re: Continuing Engine TroublesHistorical mailing list - Gerald SkerbitzSat, 11 May 1996 10:05:23 -0500 (CDT)...Also, the Bentley describes a procedure to check the Hall control unit. On the bottom left of 28.37 it says that if you...
- Re: DigiJet Hall Control Unit Maint' Point & PollHistorical mailing list - OlRivrRatFri, 23 Feb 2018 17:49:10 -0700On 23 Feb , 2018, at 2:21 PM, Neil N wrote: > Did you use thermal compound similar-same as type used for computer CPU...
- Re: Switched 12V power in Engine compartment and hall unit to ecu
question. (1984 van)Historical mailing list - mark drillockWed, 28 Jun 2006 10:09:28 -0700...1 comes > from the AEM hall unit and when grounded shows just under battery > voltage, and 13 is from a relay which shows battery...
- Re: Switched 12V power in Engine compartment and hall unit to ecu
question. (1984 van)Historical mailing list - Sudhir DesaiWed, 28 Jun 2006 13:26:57 -0400...Now what to do with the Hall unit +12v out. Sudhir On 6/28/06, mark drillock <drillock@earthlink.net> wrote: > Good raw switched...
- Re: i dont know!Historical mailing listFri, 20 Sep 1996 11:36:27 +0200...When the shutter moves out of the way and Hall voltage is produced, the control unit cuts off primary circuit current, the coil's...
- Re: Hall Sender VideosHistorical mailing list - Neil NFri, 29 Nov 2013 09:05:36 -0800...The first video shows the author shorting the middle pin of the hall connector to ground to test if the "computer controller is good...
- HELP 1985 Westy Losing PowerHistorical mailing listThu, 3 Oct 1996 21:13:33 -0700...Lost ignition in Arizona, replaced Hall sender in distributor and Hall generator (control unit) Power problem reapeared in Nevada running north on 95. Seems...
- Euro-Drive: 84 Volkswagen VANAGON, No-startHistorical mailing list - "Charles Barnes (by way of Derek Drew )"Wed, 5 May 1999 12:58:55 -0400...hall generator,Idle stabilizer ,hall control unit , coil, wires, plugs, OK CLeaned all grounds on engine replacedfuel inj. ,control unit ,same problem -control unit...
- Re: Installing Idle stabalizer.Historical mailing list - Greg MarshallTue, 16 Apr 2002 21:12:41 -0400...Three wires run to the hall control unit, and three > wires run of to the distributor. The idle stabilizer has to plugs, a > short...
- Fuel Inj SyncHistorical mailing list - Vahid LajevardiWed, 17 May 95 10:44:37 PDT...So, then these pulses go to the fuel injector control unit, and there the control unit has to fire up the injectors at the...
- Re: Emisson Control unit questionHistorical mailing list - Doug AlcockWed, 11 Jun 2003 13:33:48 -0400...From that point on the ECU runs the pump whenever it >see pulses from the hall unit in the distributor.
- Re: Removing clip from Hall unitHistorical mailing list - d spenceMon, 5 Sep 2005 17:20:40 -0600...Anyway, I want to remove the connector to the Hall unit (mounted on the side panel next to the idle control unit to check...
- Re: Low idle, let's take some bet's!Historical mailing list - Dave ArthurMon, 20 Jul 2009 07:59:42 -0300...The ONLY was the idle control box knows how fast the engine is going is through its connection to the the distributor hall sensor...
- Re: '85 Ignition Control UnitHistorical mailing list - neil nTue, 23 Mar 2010 11:12:35 -0800...Maybe use a standard VOM?? And, under Digijet, there is a note saying: "Two different types of Hall control units can be installed" (don...
- Re: WTB: Injector Driver ModuleHistorical mailing list - Rocket J SquirrelMon, 20 Aug 2012 15:53:30 -0700...The part number you refer > to is correctly called an Ignition Control Module - runs the Hall Unit > on the distributor. Fits 79 Cal Bus...
- ECU Chip Upgrade and Digifant ToolHistorical mailing list - Daniel DanrichWed, 13 Sep 2000 18:30:29 -1000...is coming from the Van So Control Unit goes out to wires -----> * Oxygen sensor * Ignition coil * Hall sender * Coolant temperature sensor * Fuel injectors * Throttle...
- AMP Part Numbers for 25 pin Digifant connectorHistorical mailing list - David MarshallMon, 11 Oct 1999 23:43:13 -0700...Stabilizer (Pin 3) 24 -- No Connection -- 25 G Hall Control Unit (Pin 6) Hall Control Unit Mfg by Telefunken - VW Part Number 191 905...
- Re: Rostra All-Electronic Cruise ControlHistorical mailing list - Ray ReinhardThu, 11 Jul 2002 17:54:40 -0700I would be interested in putting one of these cruise control units in my '86 TiiCo Westy. Being a total novice at such things...
- Re: Low idle, let's take some bet's!Historical mailing list - Benny boyMon, 20 Jul 2009 07:55:27 -0400...The ONLY was the idle control box knows how >fast the engine is going is through its connection to the the distributor >hall sensor...
- Re: New symptoms (still not running right)Historical mailing list - Geza PolonyTue, 30 Oct 2007 11:26:05 -0400I've never experienced this kind of problem, but I would start by testing the Hall sender and Hall control unit per Bentley. That...
- Hall Control Unit and timingHistorical mailing list - Walter EvensSat, 16 Feb 2002 20:50:35 -0800...I had an extra Hall unit off another '85 GL. Same make and model number on unit. The swapped unit seemed to change the...
- Re: Hall Control Unit and stallingHistorical mailing list - Geza PolonyFri, 21 Dec 2007 18:26:42 -0500...They're so tiny that if they moved around a bit, the turning sender unit would take them out in a second. And in...
- Idle stabilizer control unit...? Do they go bad?Historical mailing list - jesse johnsonSun, 22 Feb 2004 16:03:40 -0500...Do the Idle Stabilizer Control Units ever go bad? I pulled mine and cleaned the terminals... and no change. Anyone had this go bad...