| Subject: | Re: Temp II sensor |
| From: | Lawrence Johnson |
| Date: | Sun, 2 Jan 2000 18:25:38 -0500 |
John, my Bentley manual (pg. 24.45) has a chart of resistance vs. temperature for the Temp II sender. Your reading of 2800 ohms corresponds to 15 to 20 C (59 to 68 F) whicj is about right for ambient (garage) temperatures (except here in the frigid north). -Larry John Lauterbach wrote: > It would be appreciated if someone could confirm a resistance measurement > for the Temp II sensor. I am getting 2800 ohms at an ambient temperature > (presume van is at ambient since it hasn't run in over 24 hours) between pin > 2 on the cable leading to the ECU and ground (alternator shell or other > point on frame). What I am calling pin 1 on cable leads to pin 7 on > Ignition Control Module. > > Thank you very much in advance. > > John Lauterbach > Macon, GA