| Subject: | Re: another fan question |
| From: | David Beierl |
| Date: | Sat, 5 Feb 2000 12:25:33 -0800 |
At 09:00 PM 1/27/2000 -0500, David Cooper wrote: >The fan in my 82 Westy has stopped working. It doesn't work on any setting. >I took out the switch and there is power coming to it. When I turn the >switch to any of the three on settings there is power going to all of the >wires coming out the back. So is there another fuse between the switch and >the fan or is my fan dead? It looks as though there is only the one power >line coming from the fuse panel and the three wires leaving the switch to the >fan. Just thought I would seek some wisdom from the list before I tear into >the dash removal. Find the ground wire coming back from the blower and make sure it's properly grounded. For AFC it should be a 16ga brown wire going to ground connector 13 behind the dash. david David Beierl - Providence, RI http://pws.prserv.net/synergy/Vanagon/ '84 Westy "Dutiful Passage" '85 GL "Poor Relation"