At 11:30 4/14/2000, Per Lindgren wrote:
>I had problemes with ignition noise in the stereo system on my previous 88
>Syncro. I put on additional ground strap to the alternator from the left head,
>and also connected the strap to the mechanical fuel punp blockoff (engine case
>grounds ok), the right side head and the right side of te engine compartment,
>in addition to the house on the alternator. The noise didnt go away, but the
>engine was sure grounded well. The wire was 2,5 mm2.

For RF grounding you *really* want to use braid (or strap if vibration
isn't a problem).  Radio frequencies travel along the surface of a
conductor and skip the inside, so you want as much surface as
possible.  For real fanatics there's some stuff called Litz wire where
every strand is individually insulated and then the whole braided together
-- a real bear to solder since you have to clean every strand first.  I
doubt if it comes in large gauges anyway.

david