| Subject: | Re: Teflon tape difference: Propane Leak solved |
| From: | Alistair Bell |
| Date: | Fri, 5 May 2000 09:35:18 -0700 |
As a general rule...don't use any teflon tape on gas line connections. One
problem with it is the chance of bits of tape coming losse and blocking
regulators, jets etc.
A much better, albeit messier, solution is 3M's pipe sealant compounds (501
is one of the varieties). Its is a white paste in a tube that smells a bit
like Loctite and has the same anaerobic curing characteristic. It is messy
("damn, that white shit gets everywhere" is now a catch-phrase after a
recent gas line installation at work).
Alistair
>One is yellow. The other is white.
>
>Interestingly, my propane guy (and I seem to recall the instructions to my
>regulator confirmed) that teflon tape isn't needed/isn't good for propane
>fittings. I' don't know anything more about it...
>
>G. Matthew Bulley