| Subject: | Re: Attn: Successful Subaru transplants: heater control solution? |
| From: | Rico Sapolich |
| Date: | Sat, 20 May 2000 10:02:56 EDT |
In a message dated 5/20/00 1:55:39 AM, thewestyman@MINDSPRING.COM writes: << One oddity of the Subaru engine is that the coolant flow to the heater core must be constant, i.e. the flow cannot be restricted or shut off, as this will cause the engine to run hot or overheat. Has someone designed or used a three-way valve, or other type bypass system that will allow the coolant to be closed off as normal, to the heater core, but at the same time allow the coolant to continue to flow back to the engine in a completed circuit? Any ideas? Thanks! Karl M Westy Ventures >> Karl, You have the solution. A shunt in the loop via a 3-way, 2 position valve with the CORRECT flow pattern will accomplish what you want. I checked for one but, I couldn't find one quickly with hose barbs. Surely, they are made. There is nothing wrong with using a threaded valve with hose bard adapters; it's just not as svelte. Another way is to use 2 stop cocks. That is even less svelte but accomplishes the same end. One problem with this hookup, which a 3-way circumvents, is that someone not familiar with the valving arrangement may inadvertently shut off the loop. Rich