Subject:Re: Troubleshooting 'Frig Cooling Problem
From:Bill Davidson
Date:Wed, 14 Jun 2000 08:51:53 -0700

You're right!
I just looked it up in the Dometic 182B owner's manual.
Still, it might be the thermostat anyway... it's possible that it could work
better on the 120 v power than when on propane... don't ask me why.... David
B got any insights here?
Bill

----- Original Message -----
From: "Jay L Snyder" <Jay.L.Snyder@usa.dupont.com>
To: <vanagon@GERRY.VANAGON.COM>
Sent: Wednesday, June 14, 2000 8:30 AM
Subject: Re: Troubleshooting 'Frig Cooling Problem

> I think it is the other way around.  It runs w/o the thermostat on 12V DC
> and the thermostat works on 120V AC.  If you were camping with the 120V
> hook-up, you wouldn't want the fridge running wide-open.  The 12V DC is
> just to get you from place to place.
>                                                         Jay
>