| Subject: | Re: propane fill |
| From: | Alfred Bagdan |
| Date: | Tue, 22 Aug 2000 16:52:31 -0600 |
Almost right. When the liquid propane comes out the bleeder valve, the tank is about 80% full of liquid propane. Anymore is unsafe. I thought any propane filling attendant had some training in this. Alfred 85 Westy ----- Original Message ----- From: "michael schiesser" <drschiesser@bigplanet.com> To: <vanagon@GERRY.VANAGON.COM> Sent: Monday, August 21, 2000 11:09 PM Subject: propane fill > Here's how I understand it. THere is a propane bleeder valve up above where > the big thing fits on to fill (intake). To fill with propane, one opens the > bleeder valve be turning it counterclockwise and when the liquid propane > (whitish color) gets to the top of the tank, it will come rushing out the > bleeder valve and they know it is full, and then they should screw in the > bleeder valve clockwise to close it again. I agree that most of these guys > are idiots and I have tried to learn my knowledge from more experienced > types and it has been a while for me too but I think that is the deal. > > Michael Schiesser > 89 Westfalia > Seattle