| Subject: | Re: cooling system modification, OK? |
| From: | Karl F. Bloss |
| Date: | Sun, 29 Oct 2000 13:48:02 -0500 |
Whatever else you do, do not change the diameter of the tubing such that it's smaller than the original. Flow for a pipe changes with the 4th power of diameter. For example, a 18mm pipe will only have about 65% of the flow capacity of a 20mm pipe. -Karl Karl & Kristina Bloss - Trexlertown, PA '00 Wannabusser "Julia" '87 Westy Weekender "Bev" - 201K Miles '85 Westy Camper "Fred" - 39K Miles http://www.enter.net/~bloss/vw - vanagon@makarov.com US West Trip 2000: http://www.enter.net/~bloss/vwtrek PA/NJ/DE/MD area VW bus "group" http://www.enter.net/~bloss/vw/pavanagon LINUX - for IQs higher than 98
Have something to add on this topic today? Revive this thread in the forum »