| Subject: | Re: High voltage havoc from coil? |
| From: | Larry Alofs |
| Date: | Mon, 15 Jan 2001 14:44:53 -0600 |
David Beierl wrote: > At 04:00 PM 1/15/2001, Karen Olson wrote: > >I had the alternator bench tested and it seemed fine. > > Yes, that's not in doubt. But the alternator will put out 120 volts if you > let it...I'd seriously suggest to measure the system voltage with the motor > running at 2500 rpm or so. If it's showing sixteen volts then you have a > definite regulation problem. Or fifteen, for that matter. Automotive > regulators will typically hold voltage to about 13.9 max (which is a > not-very-satisfactory compromise but we won't open that can just now). > > david > > David Beierl - Providence, RI > http://pws.prserv.net/synergy/Vanagon/ > '84 Westy "Dutiful Passage" > '85 GL "Poor Relation" I second David's ideas. The high voltage circuit from the coil can not supply enough *current* to blow out a brake lite bulb. The most likely way it could happen is if the system voltage is too high when you happen to step on the brakes. The voltage regulator should not let it get very much over 14 V. Larry Chicago