Skip to main content
Gerry | Vanagon
Checking account...
← vanagon.com home · Continue the discussion in the forum
VanagonEuroVan
Subject:Re: [Syncro] AFM testing
From:Dana Morphew
Date:Sun, 4 Mar 2001 08:29:12 -0800

Check for ohms with one lead from a tester connected to 2 and the other
lead connected to 3.  It will change as you move the flap; if it changes
(up or down) without flat spots, it's OK.

-Dana-

> I have my AFM out of the vehicle. and in front of me with my multimeter.
> Can any one tell me which pins I need to connect to, for checking the meter?
> They are not numbered, so if you could tell me from the prospective of
> looking straight at the connection on the AFM.
> Is it resistance or volts that I need to watch as I move the flap?
> Is it just a smooth increase in the numbers or is there a set range of
> numbers?
> I don't have my Bentley or the vehicle with me at this time, only the AFM it
> self minus the air box.
>
> Thanks
> Glen

Have something to add on this topic today? Revive this thread in the forum »