Subject:Re: Intermittent Starting problem
From:Terry Kay
Date:Mon, 5 Mar 2001 22:57:03 -0600

Larry,
Not always true---
New starter,
New ignition switch,
New neutral safety switch,
New wire to starter solenoid from neutral safety switch,twice the
diameter of stock.
Still suffers from occasional, no start syndrome.
Wired in a auxiliary starter button from the battery, to the starter
signal wire, off the neutral safety switch, to the solenoid----problem
solved.
Took all of 45 minutes to solve this PITA problem.
The relay will also cure this. but I was in a hurry, and I didn't have a
relay, but had a starter button off a D-8 Caterpillar.

Later,

  ______________
 |[  ] [  ] [ ]\
 |    |    |    |
||-(())----(())-|

Terry 85 GL