| Subject: | Re: 1.9 l question |
| From: | David Beierl |
| Date: | Tue, 15 May 2001 09:15:07 -0400 |
At 07:45 AM 5/15/2001, puzerewski wrote: >Here is the problem. Coolant in the system, needle on gauge cluster all the >way to the left and red light blinking. Where is the sensor located? I >figure there is a wire off. The temp sender will give a zero gauge if it falls off. I can't tell if "left" is hot or cold in your case -- if hot, then check the wiring to the coolant level sensor at the expansion tank. Shorting that connection should make the system think there is coolant. If cold, then either the level-sensor as above or else the blinker circuit in the gauge itself, or the gauge is not getting enough voltage (needs 9.5-10.5v at the gauge). david David Beierl - Providence, RI http://pws.prserv.net/synergy/Vanagon/ '84 Westy "Dutiful Passage" '85 GL "Poor Relation"
Have something to add on this topic today? Revive this thread in the forum »