Subject:Re: Vibration induced electrical failure
From:David Beierl
Date:Thu, 14 Jun 2001 14:51:18 -0400

At 01:56 PM 6/14/2001, Scott De Santi wrote:
>Oh great and wise list....HELP!

Beg some more...maybe grovel a little?

>ruts.  At this time, the headlights extinguished, the overhead fan, and
>the wipers all quit (YIKES!).

Lights, fan, wipers -- classic combo (also the rear defroster) because
those are the circuits served by the load reduction relay in position 8 (#2
in row closest to fuses -- #3 is empty) of the fuse/relay panel.  Look
there, grasshopper.  That relay is driven from the X terminal of the
ignition switch which also feeds the X terminal of the light switch --
double bk/y wire from light switch (2.5 to ign, 0.5 to panel).  The X
terminal is ON with ignition but OFF when cranking.

david

David Beierl - Providence, RI
  http://pws.prserv.net/synergy/Vanagon/
'84 Westy "Dutiful Passage"
'85 GL "Poor Relation"