| Subject: | Re: Vibration induced electrical failure |
| From: | Dave Baker |
| Date: | Thu, 14 Jun 2001 14:42:46 -0500 |
Damn, David! I'm sure glad you're on our side! Dave in KC 85 Westy http://members.fortunecity.com/davebaker1 ----- Original Message ----- From: David Beierl <dbeierl@ATTGLOBAL.NET> To: <vanagon@GERRY.VANAGON.COM> Sent: Thursday, June 14, 2001 1:51 PM Subject: Re: Vibration induced electrical failure > At 01:56 PM 6/14/2001, Scott De Santi wrote: > >Oh great and wise list....HELP! > > Beg some more...maybe grovel a little? > > > >ruts. At this time, the headlights extinguished, the overhead fan, and > >the wipers all quit (YIKES!). > > Lights, fan, wipers -- classic combo (also the rear defroster) because > those are the circuits served by the load reduction relay in position 8 (#2 > in row closest to fuses -- #3 is empty) of the fuse/relay panel. Look > there, grasshopper. That relay is driven from the X terminal of the > ignition switch which also feeds the X terminal of the light switch -- > double bk/y wire from light switch (2.5 to ign, 0.5 to panel). The X > terminal is ON with ignition but OFF when cranking. > > david > > > David Beierl - Providence, RI > http://pws.prserv.net/synergy/Vanagon/ > '84 Westy "Dutiful Passage" > '85 GL "Poor Relation"
Have something to add on this topic today? Revive this thread in the forum »