| Subject: | Re: Frustrating NON START Solved |
| From: | Karl Wolz |
| Date: | Fri, 22 Jun 2001 11:02:52 -0700 |
Do I claim to be an expert? NO! My understanding is that one of the relays is for the fuel pump, while the other is for the entire fuel management system. Heck, I don't even really know what that means! But it IS my understanding. Karl Wolz ----- Original Message ----- From: "Lawrence Johnson" <larry_avery.johnson@SYMPATICO.CA> To: <vanagon@GERRY.VANAGON.COM> Sent: Friday, June 22, 2001 9:21 AM Subject: Frustrating NON START Solved > Hope you can benefit from my frustrating experience: > > The van would cough but not start. > -Checked that I had spark > -Checked that I had fuel > -Checked that the Idle Stabilizer valve buzzed > -Checked with Darrell Boehler's Digitool that all electrical were correct > > Found a broken wire at the coil, fixed it, but it STILL DID NOT START > > -Checked the fuel pump (funny shouldn't it vibrate when it first pumps up?) > -Recheck the fuel pressure (pressure but shouldn't it squirt in my eye?) > -Check the plugs (seem ok but put in new ones anyway) - STILL NO START > -Check all grounds, clean all contacts (I'm about to give up soon) > -put my finger on the two fuel pump relays (hey, only one clicked) > > INSTALL NEW FUEL PUMP RELAYS > THE ENGINE STARTS AND RUNS LIKE A DREAM > > -Larry > '86 Syncro Westfalia >