Subject:Re: Fridge or Battery relay
From:David Beierl
Date:Thu, 26 Jul 2001 17:21:01 -0400

At 04:45 PM 7/26/2001, pensioner wrote:
>The original has a diode in it and is not the standard cube relay.  The
>diode is part of the alternator sensing circuit that disconnects the fridge
>when the alternator is not charging the battery.  The hella unit does not

Are you sure?  Are you maybe thinking of something else?  Bentley shows a
perfectly ordinary SPDT relay, energized through the alternator D+ terminal
and grounded by way of the starter solenoid (50 terminal on the ign
switch).  This last bit is to my mind unnecessary -- it prevents the relay
from closing while you crank the engine, but I've never heard of a Bosch
alternator that would charge while cranking so I think it's moot...

Bentley 97.32b track 26...

:)
d

David Beierl - Providence, RI
  http://pws.prserv.net/synergy/Vanagon/
'84 Westy "Dutiful Passage"