| Subject: | Re: 84 vanagon cooling system |
| From: | David Beierl |
| Date: | Fri, 16 Nov 2001 10:39:16 -0500 |
At 10:57 PM 11/15/2001, Edward Barone wrote: >I changed my waterpump and now I cant get the coolent to bleed out the >radiator bleeder. I tested the thermostat and its ok. Took the radiator off >and it seema to be clear, water goes in and out all four holes,intake , >outlet, bleeder, and temp sensor holes. The heaters work. The inlet hose to >radiater gets HOT but the outlet hose stays cold???? Any Ideas >please,thanks................ Arrgghh, should have read the original post. Really only three choices -- the pump is not pumping the coolant out of the engine, there is a clog in the radiator or the lines, or the thermostat isn't letting the coolant back into the engine. Since the heater is working I vote for number three -- but the heater and the cooling loop run off different outputs from the pump, so I wouldn't let the pump entirely off the hook. Also the no-bleed suggests the pump, thus contradicting the heater. Does the bleeder bolt have a groove down the side, and/or did you remove it completely? And of course it would be very embarrassing to find that a rat had crawled into one of the big lines when it was open... :( Not much help, sorry -- but the system *is* deterministic. It's not simply cursed (though by now it may be very thoroughly cursed indeed, depending on your temperament <g>). d David Beierl - Providence, RI http://pws.prserv.net/synergy/Vanagon/ '84 Westy "Dutiful Passage" '85 GL "Poor Relation"