Subject:Re: 84 vanagon cooling system
From:Andrew M Fox
Date:Fri, 16 Nov 2001 06:48:12 -1000

how fast are you running it?  with the front end up the h20 pump wont pump
the coolant up to the the raditor bleed screw when idling.  you will have
to run it about 2000 rmp (on an 86) to get the coolant to come outthe
bleed screw higher or lower rpm's depending on how high the front of the
van is.  if you carefuly inspect a vanagon radiator the coolant goes in
the bottom then has to get pushed all the way up the height of the
radiator before encountering hte bleed screw and then "waterfalling"
through hte heat exchanger before going out the outlet.  I guess this is
one consequence of piping coolant 10 feet to the radiator?

Let us know how you make out.

Andrew Fox
86 Westy
Ft. Collins CO
www2.hawaii.edu/~andrewf/vanagon/links.htm

On Thu, 15 Nov 2001, Edward Barone wrote:

> I changed my waterpump and now I cant get the coolent to bleed out the
> radiator bleeder. I tested the thermostat and its ok. Took the radiator off
> and it seema to be clear, water goes in and out all four holes,intake ,
> outlet, bleeder, and temp sensor holes. The heaters work. The inlet hose to
> radiater gets HOT but the outlet hose stays cold???? Any Ideas
> please,thanks................
>  Ed Barone
>
> 84 Westy
> 73 Westy
> 66 Bug
>

Have something to add on this topic today? Revive this thread in the forum »