| Subject: | Re: I fried something (front heater blower) |
| From: | David Beierl |
| Date: | Mon, 3 Dec 2001 00:55:28 -0500 |
I don't think your problem is the blower. I'd pull the battery ground and lower the fuse panel -- start looking around for fused/melted/shorted wiring. If nothing is obvious I don't know better than to start tracing the affected circuits with the Bentley diagrams and choice of meter or maybe test light. If you have trouble making sense of the schematics I can help. d At 12:21 PM 12/1/2001, John Baker wrote: >Driving down the road yesterday in my 83.5 Water cooled vgon when I notice >the front heater blower does not seem to be blowing very hard. Start to >smell a burning smell, lasts for a few minutes then the blower stops >working completely. As this happens, I notice that my high beam\low beam >switch on the headlites no longer changes the brightness of the lights. I >also see that when I turn on my turn signals, the headlite indicator dash >bulb begins flashing in time with the turn signal, AND my backup lights >are staying on whenever the ignition switch is on, OH SH*T, what did I >do. Drove home and then after checking all the fuses (all appear fine), I >started the bus again and I still have no heater blower or High beams, but >the reverse lights are now off and the headlite indicator dash bulb no >longer flashes with the turn signal indicator. Anyone have any ideas what >I may have fried?? How much of a PITA is it to put in a new heater blower?? David Beierl - Providence, RI http://pws.prserv.net/synergy/Vanagon/ '84 Westy "Dutiful Passage" '85 GL "Poor Relation"