At 03:40 PM 12/13/2001, EarthNOW! wrote:
>We used a larger gauge wire than was in the kit to tie the two batteries
>#10........

That would explain your blowing fuses.  The smaller wires act to limit the
current flowing through the circuit.  I have not yet seen it proved that
they limit it *enough* -- but your finding that #10 wire requires a 20-amp
fuse is consistent with the theory.