Subject:Re: non-stock relay turnsignal problem... (longer than it should be)
From:David Beierl
Date:Wed, 9 Oct 2002 09:51:04 -0400

At 03:56 AM 10/9/2002, Damon Campbell wrote:
>Current wiring solution/problem:  SPDT Relays wired in series after turn
>signal switch and in parallel with parking lights.
>
>-bk/w (18) coming from turn signal switch into terminal 86 of relay (about
>8" from switch)

...and then to where it was going before

>-bk/w (18) coming out of terminal 85 of relay to wherever it was going in
>the first place

Nuh-uh.  Ground this one.

david

--
David Beierl - Providence, RI
  http://pws.prserv.net/synergy/Vanagon/
'84 Westy "Dutiful Passage"
'85 GL "Poor Relation"