Subject:Re: heater & ventilator question
From:Timothy Hannink
Date:Fri, 8 Nov 2002 06:11:22 -0800

There are two ways to fix this problem.

The first is to renew all the foam seals in the air
distribution housing. This involves pulling the
fascia, splitting the distribution box, replacing all
the foam rubber seals and re-installing everything. If
you plan on having the van a while, eventually you
will want to do this.

The second way is easier. Remove the lower heater vent
panel (in front of the shifter) and cut some foam
rubber blocks to fit inside the rectangular areas in
the cover.

I typically leave the blocks in place until it's cool
enough to use the heater, then I pull them out and
throw them in the glove compartment. As soon as the
weather is warm enough and I need to use the A/C, I
re-install the blocks.

Good luck,

Tim

--- Pat Callaghan <patcal@CYBCON.COM> wrote:
>      I always have some kind of air coming from my
> lower heater vents.  It is either hot or cold
> depending on where my second lever is.  Is this
> right?  Is there no way to stop all air from coming
> through those lower outlets?  Thanks.
>
> Pat Callaghan
> 87 Westy GL
> Portland, OR.
> www.patcal.com

__________________________________________________
Do you Yahoo!?
U2 on LAUNCH - Exclusive greatest hits videos
http://launch.yahoo.com/u2

Have something to add on this topic today? Revive this thread in the forum »