

| Subject: | Re: 91 GL Running hot still...what next? |
| From: | Andrew Fox |
| Date: | Thu, 28 Aug 2003 12:31:07 -0600 |
Rich left out an important detail: The coolant won't reach the radiator and radiator bleed valve until the t-stat opens. So you should not try to open the radiator bleed valve until the t-stat opens. I usually run the van at 2000 rpm in the driveway until the radiator fan comes on once which is a sure sign that t-stat has opened and coolant is reaching the radiator, usually takes about 10-15 minutes at 2000 rpm in the driveway to open the t-stat and reach normal operating temperature. Andrew Fox > Follow a basic bleed procedure: cold engine, remove the coolant tank cap, > start engine, turn the valve on the thermostat housing to the left, rev the > engine up to about 2K and hold it there (might want an assistant for this > part), open the bleeder valve on the radiator (you can remove it to get lots > of air out faster but be ready to put it back on). > > If you don't have anything coming out of the radiator bleeder then you have > a blockage. > > Hotch > Richard Hotchkiss > http://www.hotstrings-inc.com > > > > Date: Wed, 27 Aug 2003 16:53:01 -0400 > > From: John Meeks <jmeeks@GASLIGHTMEDIA.COM> > > Subject: Re: 91 GL Running hot still...what next? > > > > Dan, > > Stop!! Don't prise the thermo bleed cap. On your model it's really a valve > > that will pass air into the bleed ring that runs around the top of the > > engine compartment. Try parking on a steep hil or jacking up the rear. Run > > it up to temp, then open that valve. If air is your problem you should begin > > to see bubbles gurgling around in the bleed ring. > > Hope this helps, > > Regards, > > John Meeks > > Top of Lower Michigan > > 91 Westfalia MultiVan > > > > > > -----Original Message----- > > From: Vanagon Mailing List [mailto:vanagon@GERRY.VANAGON.COM]On Behalf > > Of Dan Haydon > > Sent: Wednesday, August 27, 2003 1:27 PM > > To: vanagon@GERRY.VANAGON.COM > > Subject: 91 GL Running hot still...what next? > > > > > > Hi group, > > > > At first I thought that my fan switch was not working and that > > was why I was heating up past the standard level, but then I > > noticed that the coolant is not reaching the radiator. I > > replaced the thermostat and it's still not passing through > > (turns out the old thermo was OK too). > > > > Both the metal pass tube from the thermostat and the bypass > > tube are hot, but the hose from the radiator into the > > thermostat is cool and is passing little or no coolant ( I can > > squeeze it until both sides touch). Is this most likely air in > > the lines or blockage of the radiator? > > > > I cracked the radiator bleed screw as the motor heated up to > > confirm and not so much as a whisper came from it. The bleed > > screw on the thermo housing...I twisted the plastic cap on the > > top and it seemed threaded. Do I need to prise that off to get > > to the bleed screw underneath or is that the bleed screw? > > > > Or how about a garden hose flush, would that do anything? > > > > Thanks a bunch for the continuing support on this issue! > > > > Hosed in Colorado, > > Dan Haydon >
Have something to add on this topic today? Revive this thread in the forum »