| Subject: | Re: Fixed Propane Fridge |
| From: | Germain Gagnon |
| Date: | Fri, 29 Aug 2003 19:25:14 -0400 |
Hi Shawn In the past I had a lot of difficulties to light my fridge (Westy 87) on propane. And one day, I was not able to light my fridge anymore. At that point, I decided to pull the fridge. It is not so difficult, it is just a matter of time. There is good information on the Vanagon site about the fridge. In my case, It was worthed to clean the combustion chamber. After this housekeeping, I don't even need the air pump to light my fridge. My fridge always light after 4 or 5 strokes (only the piezo). Germain ----- Original Message ----- From: "Shawn Wright" <swright@ZUIKO.SLS.BC.CA> To: <vanagon@GERRY.VANAGON.COM> Sent: Thursday, August 28, 2003 11:03 PM Subject: Re: Fixed Propane Fridge > On 28 Aug 2003 at 12:10, Malcolm Stebbins <mwstebbins@YAHOO.COM> wrote: > > > I just took a few more digi-pics and put them on > > http://photos.yahoo.com/mwstebbins These are photos > > of the controls (toggle switches) front panel > > (modified) and the controls on the top of the fridge. > > I did NOT change the wiring at all, just the switches. > > See more comments below: > > > > > --- Shawn Wright <swright@ZUIKO.SLS.BC.CA> wrote:> > > > > > Are you saying your fridge will attempt to > > > > > re-light if the flame goes out? I've > > > > > never heard this before, > > > > On my van (91 CDN westy) I #1) turn on the propane at > > the tank. #2) flip the DC switch to "on". This > > automatically starts the Piezo clicking and the red > > light flickering. #3) Turn the gas on at the fridge. > > #4) I press the by-pass switch to get the propane > > through, thus over-riding the flame sensor telling the > > unit that there is no heat (i.e. no flame). As soon > > as the gas lights, I hold the by-pass button for 6 > > seconds (to allow the heat sensor the heat up and > > signal to the unit that there's heat (flame) down > > there. #5) set the thermostat. #6 wait for the ice > > cubes :-) I rarely touch the air pump. > > I wish it were that easy on my '88... :-( > Just spent a 1/2 hour trying to get it going and all I get is the occasional loud pop. I've > trying sucking and blowing from the drain tube by mouth and shop vac, to no avail. I > can hear the gas flowing when bypass button is pressed (with hose to ear), so I know > has is there. I'm starting suspect the piezo is not firing every time, or the spark is very > weak, so it is flooded with gas, then a large pop ignites a whole lot of gas an blows > the flame out (or runs out of O2). > Any quick tips to getting it going tonight w/o pulling the fridge? Otherwise I guess I'll > be buying ice :-( > > -- > Shawn Wright > http://Zuiko.sls.bc.ca/swright > '88 Westy 375k > '85 Jetta D 263k > '85 Jetta TD 482k (retired) > ~This message sent by Pegasus Mail, the safe E-Mail alternative~ > "Friends don't let friends use Outlook"
Have something to add on this topic today? Revive this thread in the forum »