| Subject: | Re: Need quick answer on grounding problem |
| From: | David Beierl |
| Date: | Fri, 3 Oct 2003 14:03:53 -0400 |
At 01:33 PM 10/3/2003, sam.cooks wrote: >I have to take my son to a doctor's appointment in 45 minutes. Can I >use the bottom bolt holding the coil bracket in place as an alternative >ground point. Seems to be an easy yes answer, as they all connect to >that same wall, but don't want to screw up the electronics by being wrong. Sure -- just clean it up nice and shiny to get a good connection to the actual body. Suggest going behind the bracket for that purpose, rather than on top. d ps -- grounds are not necessarily as simple as they look, but you should be ok here. -- David Beierl - Providence RI USA -- http://pws.prserv.net/synergy/Vanagon/ '84 Westy "Dutiful Passage" '85 GL "Poor Relation"