| Subject: | Re: Wiring for tach and later instruments, what wire to use |
| From: | David Beierl |
| Date: | Wed, 22 Oct 2003 10:39:37 -0400 |
At 02:05 AM 10/22/2003, sam.cooks wrote: >My questions are about the wire I should use to get the signal from coil >to the wiring connector behind the fuse box. What gauge should I use? I'm using 20- or possibly 22-gauge with no trouble. I suspect 30-ga would work barring the mechanical problem of keeping it in one piece -- the actual power to drive the meter comes from the +12 supply at the panel. For mechanical integrity Bosch recommends a minimum size of 1 mm^2 IIRC, but half the wires in the Vanagon are smaller than that. Marine-grade wire is lovely stuff, and they get a lovely price for it. Use it by all means but expect all your other wiring to be jealous and start throwing little fits of pique. ;-> david -- David Beierl - Providence RI USA -- http://pws.prserv.net/synergy/Vanagon/ '84 Westy "Dutiful Passage" '85 GL "Poor Relation"