| Subject: | Re: Plumbing a second LP tank.. help! |
| From: | Larry Chase |
| Date: | Wed, 12 Nov 2003 12:06:45 -0700 |
Volks,
I'd like to second Richard's approach.
This is what I did to the RoadHaus with two exceptions.
1. I used two new tanks complete with matched "Auto Fill Valves"
purchased from Bus Depot
2. I installed a standard L-Shaped connector ahead of the regulator on
the second tank for the Propex Furnace connection.
The two tanks are connected just after the primary tank regulator via
the T-Connector that has already been mentioned.
I keep one tank valve off and one on.
Switching when one tank runs dry.
all roads lead to VW repair shops,
Larry Chase
Email: RoadGuy@RoadHaus.com
Web: www.RoadHaus.com
Cell: 480 620 8966
What: North American Road Trip
How: RoadHaus - 1990 White VW Westfalia Syncro
Today: Rapid City, SD
- - -
Date: Tue, 11 Nov 2003 12:02:58 -0700
From: "Richard A. Jones" <Jones@COLORADO.EDU>
Subject: Re: Plumbing a second LP tank.. help!
I described how I installed a second tank and BenT
put it on his web pages:
http://hometown.aol.com/realsf/howtopage2.html
Note that I did not connect high pressure. I run
each tank separately. That is, I run everything off
of one tank until it is empty and then switch to
the other. That way, I never run out of propane--
in theory. In fact, I've screwed up so now write in
my maintenance log when I fill a tank. ;-)
Richard A. Jones
Boulder, ColoradoHave something to add on this topic today? Revive this thread in the forum »