In a message dated 1/27/04 1:51:42 AM, skip@SKIPEMMERT.COM writes: << . . . it has been an absolute given that the van won't start once it's been on the highway. The relay was installed with the new starter just over six months ago. I don't know if the solenoid was replaced at the same time. . . . Skip Emmert-Keaton 1980 Westy <Ziegelstein> >> It would be a rarity for a new starter not to have a new solenoid hanging on its side. Was a new starter bushing installed in the case? If this van is an air-cooled, are you sure the pistons aren't seizing once heat soak has taken its toll after a blast down the highway? One easy thing to try which can't hurt is to install a heavy gauge grounding bond (jumper) from one of the starter mounting bolts to the chassis. I've never had to do it myself, but it seems to have its advocates. George