| Subject: | Re: Propane tank conversion.. |
| From: | Jim Arnott |
| Date: | Fri, 16 Apr 2004 17:16:51 -0700 |
Sigh... The tank on your Westy is an ASTM tank, not a DOT tank. As such it uses a completely different set of regulations than your barbeque tank. Additionally, there are no OPD devices manufactured for horizontal tanks. If a retailer refuses to fill it, find a retailer who knows the rules. (Or go to the wholesaler.) <http://www.nfpa.org/Research/NFPAFactSheets/ Propane_cylinder_Overfilling_P/propane_cylinder_overfilling_p.asp> Last bullet: # The 2001 edition of NFPA 58 modified requirements to exempt horizontal cylinders manufactured before October 1, 1998, from requiring OPDs. Jim On Friday, Apr 16, 2004, at 15:51 US/Pacific, Chris Sullivan wrote: > > I'm assuming after being refused service at two different propane > places, that there is no overfill valve on the old Westy's propane > tank. After taking a glance at GoWesty, I noticed that they sell a > new, shiny tank (with an auto-shutoff) for around $300. Given that the > tank I have looks.. well, kinda nasty it's probably time for a > replacement.
Have something to add on this topic today? Revive this thread in the forum »