| Subject: | Re: WTB: 110 VAC Electric hookup inlet |
| From: | Stan Wilder |
| Date: | Sat, 11 Dec 2004 15:51:18 -0600 |
50% JB Weld was always acceptable on my MG Midget. I'm not famillar with all VW products but I would think 50% would be acceptable at $4.00 vs. a $50.00 part. Stan Wilder Engine Ceramics 214-352-4931 www.engineceramics.com ----- Original Message ----- From: "Edward Maglott" <emaglott@BUNCOMBE.MAIN.NC.US> To: <vanagon@GERRY.VANAGON.COM> Sent: Saturday, December 11, 2004 12:56 PM Subject: Re: WTB: 110 VAC Electric hookup inlet > that gives me an idea. replace the attached male plug with a short length > of cord with male end on it. (Attach the short cord to some sturdy part of > the assembly.) Leave the box behind the existing utility inlet but cut out > the front where the attached male connector was. This leaves a space to > stuff the short cord with male end when not in use. Close the cover to > keep it tidy! Then if you pull a bonehead like me and drive off with it > plugged in, It just unplugs and doesn't break anything. > > Unfortunately I think I don't have enough left of my inlet to do this on > mine...unless I want it to be 50% JB weld. > > Edward > > At 10:24 PM 12/10/2004, you wrote: > >The simple fix for ripping things apart is this: > >Use a 1 Foot long Extension cord for the connection to the Van. > >If you drive off it will simply unplug itself frpm the long cord. > >On the water connection use a light weight PVC 90 degree coupler made up > >from hardware store parts (IE Water Hose Repair kit) and screw this part to > >the van and the hose onto it. > >If you drive off the light duty PVC just breaks off. > >You might try J-B Weld to patch up the broken unit. > > > >Stan Wilder > >Engine Ceramics > >214-352-4931 > >www.engineceramics.com > >----- Original Message ----- > >From: "Edward Maglott" <emaglott@BUNCOMBE.MAIN.NC.US> > >To: <vanagon@GERRY.VANAGON.COM> > >Sent: Friday, December 10, 2004 8:54 PM > >Subject: WTB: 110 VAC Electric hookup inlet > > > > > > > The first time I got in trouble trying to move the van with the electric > > > cord plugged in, it pulled the cord off of the end. The second time I was > > > being very careful, but... the new cord was apparently stronger than the > > > plastic of the utility inlet. It cracked all to pieces and I need a > > > replacement. I actually don't need the box on the back that covers the > > > connections. I see Bus Depot has new ones for $50, but am interested in > > > any offers. Will consider any functional condition. My old one had long > > > lost its cover and my city water inlet also has no cover, so was thinking > > > about fabricating matching covers for all 3 anyway. > > > > > > Thanks, > > > Edward > > > > > > > > > -- > > > No virus found in this incoming message. > > > Checked by AVG Anti-Virus. > > > Version: 7.0.296 / Virus Database: 265.5.0 - Release Date: 12/9/2004 > > > > > > > > > > > > > >-- > >No virus found in this outgoing message. > >Checked by AVG Anti-Virus. > >Version: 7.0.296 / Virus Database: 265.5.0 - Release Date: 12/9/2004 > > > -- > No virus found in this incoming message. > Checked by AVG Anti-Virus. > Version: 7.0.296 / Virus Database: 265.5.0 - Release Date: 12/9/2004 > > -- No virus found in this outgoing message. Checked by AVG Anti-Virus. Version: 7.0.296 / Virus Database: 265.5.0 - Release Date: 12/9/2004
Have something to add on this topic today? Revive this thread in the forum »