Subject:Re: Door electrics problem: digital vs analog meters?
From:Jim Felder
Date:Sun, 20 Feb 2005 08:52:19 -0600

Thanks, George. I'll bet this is what I was looking for. I barely knew
how to describe it, and didn't know how to do it. This will get me
going.

Since both are so cheap nowadays, is there any advantage to using a
digital vs an analog meter in a test like this?

Jim

On Feb 20, 2005, at 8:13 AM, George Goff wrote:

> In a message dated 2/19/05 7:40:16 PM, felder@KNOLOGY.NET writes:
>
> << It's like there's a voltage drop to some point below which the motor
> doesn't run. >>
>
> You have a voltage drop all right, but it is not across the motor.
> Connect
> one meter lead to a solid ground and take voltage readings at every
> connection
> point from the motor terminal back to the line side of its fuse WITH
> THE
> CIRCUIT LOADED.  Or start at the supply side of the fuse and go
> towards the motor.
> Loaded down, nearly all of the voltage drop will appear across any high
> resistance connection, whereas, unloaded you can take voltage readings
> all day and
> never see a problem.
>
> George
>