| Subject: | Re: R 134 charging |
| From: | Stan Wilder |
| Date: | Thu, 7 Apr 2005 15:59:49 -0500 |
Try running a fan with real good flow across the front condenser to see if it'll take that little extra refrigerant. If not you've probably got it over charged and that will also keep it from cooling right. Get some gauges and visit a R134 instruction page. http://www.garage-pak.com/pat-goss-info-tech/1997-it-volume1.1.cfm Stan Wilder Engine Ceramics 214-352-4931 www.engineceramics.com ----- Original Message ----- From: "Sam P" <samhp@YAHOO.COM> To: <vanagon@GERRY.VANAGON.COM> Sent: Thursday, April 07, 2005 3:25 PM Subject: R 134 charging > My '91 was converted to R 134 from R12 two years ago. Last year I added more coolant to increase the cooling ability. Now it is time for another re-charge and I question my procedure. Is the air conditioning system supposed to be running when the re-charge nozzle is attached to the place where you refill it ? Last year as I recall I just connected the hose from the R134 can and pressed the valve button on top of the can. It seemed to work and the output air was much cooler than it was before re-charging but I have the thought in mind that maybe I should have the air cinditioning running while adding coolant. Any advice ? > > __________________________________________________ > Do You Yahoo!? > Tired of spam? Yahoo! Mail has the best spam protection around > http://mail.yahoo.com > > > -- > No virus found in this incoming message. > Checked by AVG Anti-Virus. > Version: 7.0.308 / Virus Database: 266.9.5 - Release Date: 4/7/2005 > >