| Subject: | Re: help w/ charging/filling AC |
| From: | Dennis Haynes |
| Date: | Mon, 20 Jun 2005 19:14:02 -0400 |
If the system was converted, the valves should have been replaced with the R-134a valves. This is federally mandated legal requirement to prevent cross contamination of the different gasses. Dennis -----Original Message----- From: Vanagon Mailing List [mailto:vanagon@gerry.vanagon.com] On Behalf Of dusty edwards Sent: Sunday, June 19, 2005 8:22 PM To: vanagon@GERRY.VANAGON.COM Subject: help w/ charging/filling AC i'd like to use this R-134 do-it-yourself kit that i just purchased, however i'm not 100% sure if my '90 Westy has been converted or not. i bought the vehicle last summer and had it charged last summer by Ken Morgan, here in Denver..........for those of you that are familiar w/ Denver area mechanics. i don't remember much about my conversation w/ Ken in regard to this job, but i do remember him telling me that he was going to put a vacuum on the unit to extract whatever was already in there - he then filled it (with whatever) and i paid him about $75...i think. so, i pose two questions: 1. is there a way to tell if the system has been converted? 2. is there a chance that Ken filled the unit w/ R-134 (after vacuuming or cleaning it) to run off of the original system? (would R-134 even work in the old (unconverted) system?) ...if so, can i just refill the system w/ R-134? thanks for your help!!! dusty. |___|_|_|__\ |___|__-|-__| "(o)-----(o)--"