| Subject: | Re: Question adding BEHR front AC to existing rear AC |
| From: | Dennis Haynes |
| Date: | Wed, 15 Jun 2005 20:16:49 -0400 |
Only the return line should have to come back. A 2nd evaporator set up may require a larger compressor and more condenser capacity. You also need solenoids and controls for when you only want to run one. Two sets of evaporator fans may also require a larger alternator and definitely improved wiring from the existing. Simply adding a second AC may result in disappointment. Dennis -----Original Message----- From: Vanagon Mailing List [mailto:vanagon@gerry.vanagon.com] On Behalf Of Christopher Gronski Sent: Wednesday, June 15, 2005 6:16 PM To: vanagon@GERRY.VANAGON.COM Subject: Question adding BEHR front AC to existing rear AC I am bringing my van in to a local VW shop to convert from R12, replace the compressor (there is one leak in the system at the compressor - but that is getting replaced anyway). The shop indicated that they'll have to have some AC lines fabricated as part of the install, which leaves me wondering... The existing AC system goes from compressor in the rear to condensor in the front then back to an evaporator in the rear. Since the BEHR unit has its own internal evaporator wouldn't the AC line just T off of the existing lines coming out of the evaporator? Is there any reason that new lines would need to be run back to the compressor? Thoughts? Chris