Subject:Question to any fridge freak...
From:Benny boy
Date:Mon, 20 Mar 2006 22:47:29 -0500

Quick question and short story:
Fridge remove, cleaned, tested in any way i can, combustion chamber cleaned
and re-seal, fan work great, new propane tank, good flow to fridge, but
after????.

Result: Light up/start up fine the first time without "priming" on 110V,
good flame in the windows, good heat in exhaust, stable flame.... but, it
dosn't fleeze much???? (temp around 45-55F)
The thermostat as not much effect on it except when at the 0 position, it
goes in the pilot mode
I'm not sure if the flame is stong enough???? or a leak in the exhaust will
cause that.

Fridge works fine on 110V (40-44F), any suggestion??? this fridge in
question didn't work for years, but is close to freezing point on 110V and
on 12V.