| Subject: | Re: Question about Westy City Water Outlet |
| From: | Mike Collum |
| Date: | Thu, 18 May 2006 10:18:50 -0400 |
I thought that check valve (ball) was supposed to shut off the port when pressure was removed. Mine doesn't restrict flow when city water is hooked up but, before winter, I have to use a rod to push the ball in to drain any water so the line/connector won't freeze. It would appear that ball is there to keep the line clean when not hooked up. I've purchased a pressure regulator to fit between the hose and the port so as not to overpressurize and possibly break things. Mike '85 Westy Kenneth Wilford wrote: > I was having a problem with a customer's city water hook up today and I > wanted to ask some advice. I always thought this connection was just a > connector to hook at hose up to the side of the van. However there is a > check valve/ball inside the hook up. When I hook normal water pressure up > to it the ball moves and shuts off the water coming into the van. Is this > supposed to happen? What is up with this check valve? Can I just get rid > of it? Any advice would be welcomed. > > Thanks, > Ken Wilford > John 3:16 > http://www.vanagain.com > http://www.strictlyvwauctions.com > http://www.eurovan.org > http://www.vwcabrio.org > Phone: (856)-327-4936 > Fax: (856)-327-2242 >
Have something to add on this topic today? Revive this thread in the forum »