| Subject: | Re: dometic pilot goes out when thermostat turned up |
| From: | Andy Highland |
| Date: | Tue, 27 Jun 2006 22:15:11 -0700 |
This is on a '90. I am watching the green pilot LED that is below the water level. The LED is glowing when the pilot is lit. When I turn up the thermostat, it dims, then goes out. The sparker then starts up. I am unable to see a flame through the window at any point in the process. Thanks, andy On Jun 26, 2006, at 11:03 AM, Loren Busch wrote: > One quick question to assure that we are all talking about the same > thing > and using the same terms. First, what year is your Westy? I ask > because the > process for lighting the refrigerator is different in '90 and '91 > Westies > and there is another indicator light on those models that I have > seen at > least one new owner mistake for the indicator that the flame was > present. > So second question, how do you know that the fridge is lighting and > how do > you know that it is going out? > > On 6/23/06, Andy Highland <andy@420.am> wrote: >> >> My dometic lights and stays lit as long at the thermostat is left at >> 0. When I turn it up, the pilot goes out. : ( Has anyone had this >> problem? >> >> Thanks, >> andy >>