| Subject: | 88 digifant O2 readings off |
| From: | Matt Sutton |
| Date: | Tue, 4 Jul 2006 12:33:20 -0400 |
Hi folks,
Preparing for NY emissions today, and have run into some weirdness with my
O2 readings.
Test conditions: Engine at opperating temp
O2 sensor disconnected at attached to digital voltmeter
Idle stabilizing valve disconnected
Idle set ~900-950 rpm
Temp sensor disconnected after start up
Test Readings at O2 Sensor: -.54v at start
-after a minute, reading fluctuates but
averages .5v
-when temp sensor's disconnected, reading jumps
to .9v and pretty much stays there. Very small
adjustments possible at AFM, but nowhere near
where needed to reach the .5v target. There is
the some upward movement available, as high as
1.2v.
So it's this last result that's troubling me. The van runs fine. And
while it misses a little at idle, it always has. I know the 02 sensor's
doing it's job, but am worried about leaning too hard on the Cat and ECU to
compensate.
Any thoughts?
Happy 4th,
Matt Sutton
Brooklyn NY
88GLHave something to add on this topic today? Revive this thread in the forum »