Subject:Re: Having a problem with a starter
From:Dennis
Date:Fri, 11 Aug 2006 14:25:19 -0400

Ken, I had a starter in and out of my van 4 times as the rebuilders
repeatedly failed to diagnose the slow cranking problem as a bushing.  If
you have access to the equipment, a check of current draw at the battery
during starting will show abnormally high draw.  Mine was something like
600 amps.  That's likely why the ground wire is hot.