| Subject: | Temp II bad [again??!!] says DigiTool [long winded] |
| From: | Thomas Myers |
| Date: | Tue, 12 Sep 2006 08:59:53 -0400 |
I told the list back in June about my bad temp 2 sensor [ only 2 years old] Thanks to DigiTool � a new sensor from the dealer and a TPS alignment Got the van running like a top all summer. The cold mornings this month have brought back the grumpy / lumpy Start ups and random stalling. This mornings grumpy / lumpy start up with high idle had Digitool Giving me the following readings for Temp II: 4.9 with high idle. [ I think 4.9 is way off the normal scale for Temp II] I remember listees mentioning the wiring for the sensor sometimes going bad - So I opened up the engine lid.. 4.9v high idle 4.9v [ wiggling sensor wiring] 4.9v [ sensor disconnected!! ???] 4.9v [ sensor reconnected] I wait a minute [ van running total of 4 minutes] And then in 3 seconds the voltage reading goes..[ with the idle following it up and down] 4.9 � 3.2 � 3.8 � 4.9 � 4. 9 �2.8 � 3.5 � 2.8 � 2. 5 � 2.2 � 1.9 � 1.5 � 1.3 [ normal for cold] And the engine runs fine at that point. So the Temp II sensor is bad again?? This one is from the dealer and was new in June! I made a joke about carrying spares but this is crazy... And why would I still get a voltage reading With the sensor plug pulled out?? Thanks for any input. Tom Myers 90 Westy Rochester NY http://motsvan.blogspot.com/ Thomas A. Myers Designer, Industrial Design Human Interface Department Xerox Corporation 1350 Jefferson Road, 801-10C Rochester, NY 14623 (585) 427-5141, 8*227-5141 Thomas.myers@xerox.com XEROX Technology Document Management Consulting Services www.xerox.com
Have something to add on this topic today? Revive this thread in the forum »