Subject:Re: refitting propane tank
From:neil
Date:Mon, 12 Feb 2007 10:59:32 -0800

With LP in tank, open valve on regulator. Check for leaks by putting
soapy water solution on all unions. Look for bubbles on each union.

Valve on reg does not "mix" anything.

Fill valve is where attendant hooks up LP hose.

Did you replace reg. fill valve and bleeder?

Use proper precautions when working on LP system!!

AFAIK:

regulator regulates the pressure/amount of LP through line(s) to
appliances. (stove/fridge) Once valve is open, a regulated amount of
LP comes out the outlet and goes through lines to appliances. The tank
has lots of pressure when LP is in it. That pressure needs to be
regulated (lowered) to a "set" amount that appliances can proplerly
use.

i.e. you don't need to turn (open) the "open/close valve" until it
comes to a stop. 1/2 - 3/4 of the way (CCW) is fine. If reg. is
working properly, the correct amount of pressure will be coming from
outlet of reg. through lines to appliances.

IF YOU HAVE ANY DOUBTS as to how to check function of valves, look for
leaks, or finish your job, go to a licensed LP pro and have system
checked/finished.

Just my $.02

Neil.

On 2/12/07, Matthias Kuster <matthiaskuster@verizon.net> wrote:
> Hi, list,
>
> I R&R'd my propane tank,

SNIP

> Is there a big chance of leaks?? My fittings seem tight, am
> just wondering about the valve (open/close valve), as well as fill
> inlet and regulator (how does that function anyways??> Does it adjust
> the mixture? Mixture with what?).
>
> Keep on Trucking,

SNIP