| Subject: | Re: westy wiring woes |
| From: | Mark Drillock |
| Date: | Thu, 8 Feb 2007 12:25:59 -0800 |
It depends on which version of the led panel you have. The early version has a large power transistor behind the painted cover that turns on power to the pump when it thinks there is water in the tank. A round silver thing about the size of a nickel, if there you have the kind that can disable the pump when the tank level reading is NG. Used 80/81 at least but lots of panels have been swapped over the years. The simple thing is to bypass the transistor and I have done so on several early Westys that I have worked on. That way the pump always has power available Mark Nathaniel Poole wrote: > Or maybe not. before I whip out the trusty voltmeter, maybe this is > what it's supposed to do? My water tank is bone dry. When I flip the > power to the water pump nothing happens -is this normal when the tank > is empty? ALso the h20 level indicator doesn't read anything. I know > there is power as the battery level is working and other accessories. > > > Nathaniel >
Have something to add on this topic today? Revive this thread in the forum »