| Subject: | Re: Propex heater |
| From: | Karl Mullendore |
| Date: | Sat, 28 Apr 2007 11:54:07 -0400 |
Gerald, First, my apologies for the problems you are experiencing. As I explained on the phone to you a few days ago, this does sound like an altitude-related issue and one that I am aware of, it has come up in two other units that I know about. I also told you that Propex is sending larger gas jets to me that will hopefully alleviate the problem. However, I can't possibly say exactly what day they will arrive in my mailbox, nor can I fix your heater unless it is shipped back to me. It is warrantied two years from your purchase date, unless opened by someone other than myself or other authorized Propex representative. I also recommended that you verify the regulator(s) are still set to the proper pressure of 13~14 wci. The 'growl' in the exhaust on startup is normal, that is the way they all sound until the fan and burner kick up to the 'run' stage. You might also want to verify that your tanks are clean and moisture-free inside, as moisture will freeze up the regulators. If you'd like to send the Propex back for the jet upgrade once I have the jets in hand, I'll be happy to take care of that and ship it back to you no-charge. Karl Mullendore www.propexusa.com On Fri, 27 Apr 2007 23:03:14 -0700, Gerald Masar <azsun99@EARTHLINK.NET> wrote: >I recently installed a Propex HS 2000 in my '90 Westy, and increased the gas pressure >to the recommended 13"W.C. It is wired to the aux battery under the driver's seat and >I also installed a connection to run it off of an external power pack if necessary. I >have two propane tanks. I don't do cold very well :(. >So, a shakedown cruise was made last week, to the South Rim of The Grand Canyon. >Elevation just under 7,000', daytime temps in 50's and 60's, and nighttime into the >20's and 30's, and one day of cold, miserable gale-force winds. Nice to be able to >stay inside and stay warm. So far, so good. >On the 3rd morning, woke up to see the LED flashing code for low battery. Switch to >the other battery and back in business. >On the fourth morning, woke up to see LED flashing code for no gas. Okay, well the >stove still worked, but switched to the other tank anyway. Now, not okay. Still says >no gas. Switched unit off and on several times, switched tanks, still no go. >On the way home, stopped for lunch and tried it again on #1 tank. Now it works and is >still working. >QUESTIONS: >Has anyone else experienced intermittent operation under similar conditions? >I hope it isn't altitude related, because some of my favorite campgrounds are at >9,000' and 10,000'. >The instruction manual says that the red LED should dim after set temp is reached, >indicating unit is in standby. Mine doesn't, does yours? >The noise of the burner, at least until the fan speeds up and masks it, I would >describe as kind of a growling noise, not a smooth sound. What does yours sound like? > >A phone call to PropexUSA so far has been inconclusive.
Have something to add on this topic today? Revive this thread in the forum »