| Subject: | Re: Aux Battery Charging Alternatives Question for the Electrical Gurus |
| From: | Loren Busch |
| Date: | Wed, 18 Jul 2007 10:34:50 -0700 |
On 7/18/07, Dennis Haynes <d23haynes57@hotmail.com> wrote: > > Is you smart charger designed to permanently installed? If so, there > should > be no problem having the solar charger and the other battery charger > permanently connected. That is how it is normally done. Since you have the > smart switch isolating the batteries, the typical installation would be > for > the solar and 110V charger to be connected to the house battery. The > engine > alternator stays on the chassis battery. Dennis, I have in fact the exact charger you suggested, with the Charge Wizard. The one thing I noticed is that when connected to the battery but no 110 v ac going to the charger I still had the LED on the Wizard illuminated. And you are confirming my suspicion that both the solar controller and the charger can be connected at the same time. Thanks
Have something to add on this topic today? Revive this thread in the forum »