

| Subject: | Re: Auxiliary propane tank |
| From: | Dennis Haynes |
| Date: | Wed, 25 Jul 2007 17:26:53 -0400 |
How long is your trip and what equipment are you using to use a lot of Propane anyway? Fridge and stove for 2 weeks should not be a problem unless you plan to cook a lot. Dennis >From: Paul Chubbuck <paul@TAKINGFLIGHT.NET> >Reply-To: Paul Chubbuck <paul@TAKINGFLIGHT.NET> >To: vanagon@GERRY.VANAGON.COM >Subject: Re: Auxiliary propane tank >Date: Wed, 25 Jul 2007 13:37:36 -0600 > >That is the very product I was looking at this morning. I'm sure you're >correct about that being the proper way, but I don't have time to do it >that >way before I leave Friday on my trip. I had previously believed I could do >it with a simple screw-in connection. > >Paul > >-----Original Message----- >From: Dennis Haynes [mailto:d23haynes57@hotmail.com] >Sent: Wednesday, July 25, 2007 12:36 PM >To: paul@TAKINGFLIGHT.NET; vanagon@GERRY.VANAGON.COM >Subject: RE: Auxiliary propane tank > >Marshall brass sells a product called "Extend-A-Stay tee which installs >between the regulator and tank. There are a few versions that allow the on >board tank to feed a BBQ or other appliance and also connect a separate >tank > >as a source when needed. It is the proper way to connect the tank. It does >not take up much space and the existing lines can be easily cut and >re-flared to make the connections. > >Dennis > > > >From: Paul Chubbuck <paul@TAKINGFLIGHT.NET> > >Reply-To: Paul Chubbuck <paul@TAKINGFLIGHT.NET> > >To: vanagon@GERRY.VANAGON.COM > >Subject: Auxiliary propane tank > >Date: Wed, 25 Jul 2007 11:05:03 -0600 > > > >About 6 weeks ago, someone on this list told me I could get a barbecue >tank > >(propane) and a hose which would go from that tank to the inflow >connection > >of the existing propane tank and thus have an additional "stay longer" >fuel > >supply. > > > >When I went to a propane supplier today they said that won't work because > >there is a check valve which will only allow flow under the very high > >pressures provided by the fill systems. They offered a solution which > >requires a valve and splitter be installed in between the shut-off valve > >and > >the OPD valve, but that is a big job requiring the plumbing be re-done > >because there is insufficient space and the copper plumbing is already > >pinched as it is. > > > >Does anyone have experience with this? Are they correct in what they're > >telling me about that simpler solution not being workable? > > > >Thanks, > >Paul in Fort Collins
Have something to add on this topic today? Revive this thread in the forum »