Subject:Re: Dometic mystery ....more clues!
From:Roger Sisler
Date:Sun, 19 Aug 2007 14:15:29 -0400

I sent a set of pictures to the list a couple of weeks ago showing
pictures of a 1985 camper owner manuel. It has  a note about high altitude
Dometic use.

It says that the OEM burner jet is a size #24. If using the Dometic at
altitudes over 6500 ft, to change this to a #22. The #22 is smaller.

Seems to me that this smaller size can be mimicked by reducing the tank
pressure.Changing it from 11 inches of water column , to maybe 10 or 9
inches may reduce the pressure same as using a smaller jet. What do you
think?

The jet from a 182b for high altitude may or may not be avaliable this
long since the manuel was printed. It will fit the 182a if the entire
lower buirner box is exchanged, too. I called Dometic once and asked about
obsolete 182b parts.They gave me a phone number for a company that bought
their old stock. They had lots of stuff, and may have this high altitude
jet for a 182b.Dont remember the company name.