>Now I KNOW I'll get this load bar done. Too bad I can't get material >til Tuesday! > http://tubaneil.googlepages.com/1stlargeweld >Thanks guys, >Neil. Neil, Looking at your picture, I'd say you are using a 120 volt MIG. Fluxcore? That would give you marginal penetration on material as thick as in your picture. Go slowly and weave back and forth. I hold the torch with two hands, one on the trigger and the other near the tip. Hold the torch close in to the material, as little 'stick out' and possible. Plug your welder in as close to the breaker box as possible. Avoid using extension cords. Gary Lee www.vwrack.com