| Subject: | Re: Dometic Thermistor Function? |
| From: | neil N |
| Date: | Mon, 14 Jul 2008 09:15:48 -0700 |
Thanks for confirming what I suspected Roger. In my post, I wasn't certain about whether or not it contacted metal to metal. I'll be pulling my 182A and swapping in a 182B. I had redone the mastic on the 182A cooling unit. I'll be curious to look and see if I had mounted the sensor correctly. (metal to metal) If I had installed it leaving some play between each part, this may have contributed to making it hard to light in the morning. If I turned it down at night, the flame would go out. Neil. On Mon, Jul 14, 2008 at 8:49 AM, Roger Sisler <rogersisler2000@yahoo.com> wrote: > That probe needs to be tight against the rear of the aluminum evaporator. > Metal to metal contact. There is a channel along the entire length of the > evaporator's rear that the probe sticks into. A plastic cord about 1/8 inch > in diameter and 4 inches long presses in on top of it to keep it in place. > That white cord should still be around. It is probably still in the groove > and the probe just slipped out. > > It measures the temp of the aluminum plate. > -- Neil Nicholson '81 JettaWesty "Jaco http://groups.google.com/group/vanagons-with-vw-inline-4-cylinder-gas-engines http://web.mac.com/tubaneil http://tubaneil.googlepages.com/